Inspection of equipment on the shop in progress or by equipment based on the work schedule.

¢Ã Major Plants & Facilities Covered
  - Steel Works
  - Power Plants
  ( Nuclear, Thermal, Hydraulic, LNG )
  - Oil & Gas Plants
  - Refinery, Petrochemical Plants
  - Steel Structures
  - Environment Facilities
  ( Water treatment , Incineration )
  - Other Industrial Equipment & Facilities




     Pre-Inspection Meeting
¡¡

    - Determination of inspection and test procedures
    - Interpretation of specification and standards


     Qualification Test
¡¡

    - Welder qualification test,
    - Welding procedure qualification test
    - N.D.E operator qualification test


     Checking about Welding
¡¡

    - Qualified welder, welding rods
    - Welding procedure specification
    - Work schedule of fit-up, welding and heat treatment inspection



     Crane, Fan & Blower, Compressor


¢¹ Crane

- Material inspection : Chemical, physical characteristics hardness test
- Visual inspection : Welding structures, cabin
- Dimension inspection : Structures, machinery
- N.D.E : RT, UT, MT etc
- Heat treatment inspection
- Temporary assembly inspection : Girder, Crab
- Test run inspection : Temperature, vibration, r.p.m, velocity, centering, noise, current, voltage, resistance etc
¡¡

¢¹ Fan & Blower

- Visual and dimension inspection : Model, frame, flowing direction, starting method, defect in welding and casting, machining and tolerance of shafts
- N.D.T : RT, UT, MT etc
- Heat treatment inspection
- Balancing test : Dynamic test of the impeller
- Performance test : Pressure(static, dynamic), power, current, voltage, resistance, r.p.m, noise, fluid temperature, volume, efficiency, vibration, etc
¡¡

¢¹ Compressor

- Visual and dimension inspection : Surface defect of casting and forging, welding and machining defect, dimension of cylinder and liner, coating, milling of piston rod
- N.D.E : Air receiver tank (RT) shaft, piston rod (UT)
- Pressure test : Water pressure, leakage of tank
- Performance test : Volume, r.p.m, temperature, operating test of safety valves, loaded & unloaded, air circulation, noise, vibration
¡¡



     Pump, Hydraulic Cylinder, Reducer


¢¹ Pump

- Visual and dimension inspection : Model, frame, r.p.m, flange
machining, casting defect
- Pressure test : Water pressure of casing
- Balancing inspection: Impeller
- Performance test : Total water head, power, outlet volume, power, noise, bearing temp, efficiency, vibration. etc
¡¡

¢¹ Hydraulic Cylinder

- Visual and dimension inspection : Cr coating and milling condition, head machining and thickness
- N.D.E : Cylinder tube(RT). piston rod(UT) head cover welding(MT)
- Assembling inspection : Clearance in diameter between piston head and tube
- Performance test : Unloading operation, pressure, oil leakage, valve, piston rod distance, etc
¡¡

¢¹ Reducer

- Visual and dimension inspection : Machining of casing, shaft, pinion
- N.D.T : Shaft and pinion gear (UT,MT)
- Assembling inspection : Contact, backlash, cleaning
- Performance test : Inlet & outlet power, r.p.m, temperature, noise, vibration, oil leakage
¡¡




     Valve, Expansion Joint, Transformer


¢¹ Valve

- Visual and dimension inspection : Casting, surface, disc, shaft etc
- Assembling inspection : Handle, stem, disc, disc seat sealing
- Pressure test : Leakage of body and bonnet
¡¡

¢¹ Expansion Joint

- Visual and dimension inspection : Welding and machining defect, type/rate/thickness of flanges, number/length/bolt of bellows
- Pressure test : temp, pressure, holding time
- Painting inspection : no paint on rubber
¡¡

¢¹ Transformer

- Review of test report
- Visual and dimension inspection
- Assembling inspection
- Performance test : Core impedance, polarity, displacement, impedance loss, oil leakage, temp, insulation, impulse voltage
- Painting and packing inspection
- Applied codes : AWSI C57-2, IEC 76, NEMA TRI, ASTM D117, IEC 214
¡¡



     Motor, ETC


¢¹
Motor

- Review of material test report
- Review of N.D.T report
- Visual and dimension inspection
- Machining & assembling inspection
- Performance test : Core impedance, no load test, noise, vibration, oil leakage, temp, insulation
- Painting and packing inspection
- Applied codes : KSC, IEC 34, NEMA, ANSI, MGI
¡¡

¢¹ ETC

HT, Receiving, Distributing and Instrument Panel  ETC..
¡¡
¡¡

¡¡
With a safety first policy, We are conducting scrupulous supervision for the construction of strong bridges.


¢Ã Major Facilities Covered


- Steel Bridges
- Hover Structures


     SERVICES COVERED
¡¡

    - Review of specifications and drawings
    - Review of erection on site and quality assurance programs
    - Supervision of civil work related to the equipment installed
    - Supervision of piping work under and above ground
    - Supervision of surveying of location and elevation
    - Supervision of structure fabrication
    - Supervision of tank fabrication
    - Supervision of installing equipment
    - Supervision of installing rotating equipment
    - Supervision of installing boilers and furnaces
    - Supervision of electrical and instrument work
    - Supervision of welding and N.D.E
    - Supervision of painting and insulation
    - Supervision for commissioning
    - Supervision for field tests
    - Supervision of safety controls
    - Supervision of non-conformance controls

¡¡
Diagnosis of facilities is conducted while their operating, and through periodical diagnosis, people's and assets can be protected before problems take place and also expected economical and stable operation and maintenance.


¢Ã Major Facilities Covered
Refinery and petrochemical plants (nuclear, thermal, hydraulic), storage facilities (oil, gas), oil transmission lines, environment plants (incineration, water treatment), building facilities
(office, commercial, dwellings), S.O.C
infrastructure facilities, other industrial plants
¡¡


     Planning
¡¡

    - Surveying the present conditions of equipment ( forecasting the losses)
    - Analyzing the past history
    - Checking of the relevant Codes and standard
    - Selection of the inspection methods


     Diagnosis
¡¡

    - Shutdown inspection (SDI)
    - On-stream inspection (OSI)
    - Diagnosis of aged deterioration
    - N.D.E, hardness tests
    - Precision diagnosis for rotating equipment
    - Safety diagnosis
    - Diagnosis of electrical system (on-line diagnosis)


     Evaluation
¡¡

    - Inspection data analysis
    - Inspection report
    - Lifetime assessment
    - Inspection of effectiveness of facilities

¡¡